在現(xiàn)代化工、制藥、食品飲料及精細加工等流程工業(yè)中,液體濃度的實時掌握,往往直接關系到批次一致性、工藝穩(wěn)定性與合規(guī)性驗證。取樣送檢耗時長、滯后性強;固定式在線儀表部署成本高、靈活性差;而臨時性監(jiān)測需求又頻繁出現(xiàn)——如何在不中斷生產(chǎn)、不增加復雜布線的前提下,精準、可靠、即插即用地獲取多點濃度數(shù)據(jù)?
恩德斯豪斯(Endress+Hauser)推出的 Teqwave T,并非傳統(tǒng)意義上的超聲波流量計,而是一套以超聲波技術為核心、專為移動式濃度分析深度優(yōu)化的智能測量系統(tǒng)。它由一個便攜式變送器與一個插入式超聲波傳感器組成,通過聲速、溫度與密度的協(xié)同建模,實現(xiàn)對液體濃度的非侵入式、免標定、高重復性解析。作為上海闊思電子有限公司長期合作并技術支持的恩德斯豪斯核心產(chǎn)品之一,Teqwave T 在國內(nèi)多個中試平臺、GMP車間驗證環(huán)節(jié)及過程優(yōu)化項目中,已成為工程師信賴的“移動測量助手”。
Teqwave T 采用超聲波濃度測量原理——不同于依賴流速推算體積流量的超聲波流量計,它聚焦于液體介質(zhì)本身的物理屬性變化。當超聲波穿過被測液體時,其傳播速度會隨溶液中溶質(zhì)濃度、溫度及密度發(fā)生微小但可精確捕捉的偏移。系統(tǒng)內(nèi)置高精度溫度傳感器與聲速計算模型,結合預存于濃度App中的校準數(shù)據(jù)庫(如乙醇-水、氫氧化鈉溶液、糖漿、有機溶劑等常見體系),即可反演出當前濃度值(單位可為 % w/w、°Brix、mol/L 等)。
這一原理帶來三個關鍵特性:
Teqwave T 并非替代主控系統(tǒng)的永久儀表,而是填補“間隙性測量需求”的關鍵一環(huán):
? 工廠日常巡檢與異常排查:當某條管線出現(xiàn)輕微結晶傾向、換熱效率下降或pH波動時,工程師可攜帶Teqwave T快速前往多個可疑點位,同步比對濃度梯度,輔助定位問題源頭;
? 中試線與新工藝驗證:在未完成最終儀表選型前,用Teqwave T采集不同反應階段、稀釋比例、進料速率下的濃度數(shù)據(jù),為DCS系統(tǒng)配置提供實測依據(jù);
? GMP與合規(guī)支持:在潔凈區(qū)進行清潔效果驗證(如NaOH殘留濃度)、消毒液配比復核、緩沖液濃度抽查等任務中,避免開蓋取樣帶來的污染風險;
? 實驗室方法比對與校準支持:作為參考基準,與折光儀、滴定法或HPLC結果交叉驗證,提升整體分析體系的可信度;
? 設備交付與調(diào)試協(xié)助:E+H工程師聯(lián)合上海闊思電子有限公司技術服務團隊,可在客戶現(xiàn)場使用Teqwave T開展快速性能演示、傳感器安裝指導及App參數(shù)配置培訓,縮短交付周期。
| 類別 | 參數(shù)說明 |
|---|---|
| 測量變量 | 濃度、溫度、聲速、密度(衍生) |
| 測量范圍 | 濃度:依所選App而定,典型覆蓋0…100 %;聲速:600…2000 m/s;溫度:0…+100 °C(32…212 °F);密度:0.7…1.5 g/cm3 |
| 傳感器 | 不銹鋼V4A(1.4571),插入長度180 mm;IP68(配插頭)/IP66(裸頭) |
| 變送器 | IP40防護;工作環(huán)境溫度0…50 °C;含鋰電池與數(shù)據(jù)存儲模塊 |
| 顯示與操作 | 3.5" TFT彩色屏,4鍵導航,支持多語言界面 |
| 認證與合規(guī) | CE、C-Tick;符合EMC與LVD指令;適用于工業(yè)測量環(huán)境 |
Teqwave T 的價值,不在于參數(shù)表上的峰值指標,而在于它讓原本需要協(xié)調(diào)多方、等待數(shù)小時才能獲得的數(shù)據(jù),變成工程師口袋里隨時可調(diào)用的“確定性”。它不改變現(xiàn)有產(chǎn)線結構,卻悄然提升了過程可視化的顆粒度;它不要求用戶成為超聲波專家,卻提供了接近實驗室級的分析能力。
作為恩德斯豪斯在移動過程分析領域的代表性成果,Teqwave T 由上海闊思電子有限公司提供本地化技術支持、應用咨詢與快速響應服務。無論您正處于工藝優(yōu)化初期的數(shù)據(jù)摸底階段,還是面臨GMP審計前的集中驗證任務,這套系統(tǒng)都以務實、穩(wěn)健、可擴展的方式,成為連接理論模型與真實工況之間值得信賴的一座橋梁。
——它不喧嘩,但始終在關鍵處給出清晰的答案。
The portable Teqwave T offers the most flexible application possibilities for temporary in situ liquid analysis in your plant or laboratory. With just one device, you can monitor concentration values at various measuring points and thus maximize your product quality at minimum operational expenditure. The mobile transmitter with its customizable app concept and the pre-configured measuring points allows you to use Teqwave T perfectly matched to your production needs.
Easy, fast and efficient – real-time in situ liquid analysis
Versatile applications – one device for changing tasks
Highest process safety – reliable metering due to robust, maintenance-free sensor
Cost-saving – surveillance of product quality without...
The acoustic waveguide measures precisely and reliably, even the smallest changes are detected
Temporary concentration measurement of liquids at various measuring points in plant & laboratory.
Device properties
Accurate and independent of flow profile
Insertion length: 180 mm (7")
Robust, portable transmitter with Li-ion battery 2300 mAh
Large color display with 4 operating keys
Integrated data storage for max. 3000 measured values
Ultrasonic concentration
智能的移動濃度測量解決方案,應用靈活,為您量身定制。使用簡單、快速、高效:實時在線液體分析。能夠臨時測量工廠和實驗室中多個測量點的濃度。
應用廣泛:單臺儀表滿足多種測量任務要求。最高過程安全性:傳感器堅固耐用,免維護,計量可靠。使用經(jīng)濟:產(chǎn)品質(zhì)量監(jiān)督無需取樣抽檢。高測量精度,不受流場的影響。插入深度:180 mm (7")。
按需定制:創(chuàng)新的app理念,改造升級簡單,輕松應對各類測量任務。無需具備計量專業(yè)知識即可快速、直接操作儀表:預設置測量點。高效工廠監(jiān)測:在無外接電源的條件下最多可以移動操作8小時。堅固耐用的便攜式變送器,由2300 mAh鋰電池供電。大尺寸彩色顯示屏,配備4個操作按鍵。
插入深度:180 mm (7")
濃度
溫度
聲速
密度:±0.01g/cm³
溫度:±0.5K
聲速:2m/s
濃度符合濃度app中的數(shù)據(jù)表,最大為0...100 %
聲速:600...2000 m/s
溫度濃度app數(shù)據(jù)表,最高0...+100 °C (32...+212 °F)
密度:0.7...1.5 g/cm³
0...100 °C (32...212 °F)
變送器:0...50 °C (32...122 °F)
傳感器:0...40 °C (32...104 °F)
不銹鋼V4A 1.4571
傳感器:IP68(帶電纜插頭)、IP66(無電纜連接頭)
變送器:IP40
3.5" TFT彩色顯示屏,帶4個操作按鍵
鋰電池(2300 mAh)
CE認證、C-Tick認證
......................................................................................................................................................................................................................................................................................................................................